              | Products
 |  
              |  |  
              | 
                
                  | 
                    
                      | 
 | Technical Specification 
                            
                              | Mechanical |  
                              | 
                                  
                                    | Test Name | Test Requirements |  
                                    | Tensile | 0.35mm / >20 N (Vertical) / >3N (Horizontal) |  
                                    | Torsion | 0.50mm / >40N (Vertical) / >6N   (Horizontal) |  
                                    | Bending | 0.60mm / >50N (Vertical) / >8N   (Horizontal) |  |  |  |  
                  | Electrical 
                      
                        | Test Name | Test Values ∆R | Norms |  
                        | Connection Resistance | < 1 mΩ≤ 2.5 mΩ (per contact point
 ≤ 7.5 mΩ total)
 | ASTM B539-96, IEC 60 512-2-2a |  
                        | Vibration | < 1 mΩ, ≤ 2.5 mΩ | ASTM B539-96, IEC 68-2-6 |  
                        | Insulation Resistance | >  50 GΩ (50x109 Ω ) | IEC 60 512-2-3a |  
                        | Dielectric Strength | ≥ 2 kVAC   x 60sec | IEC 60 512-2-4a |  
                        | High Voltage Surge | 1.2/50µs  ≥  3.6kV | IEC EN 60 950 |  
                        | Surge Current Test | 8/20µs 10kA | ITU T-K.12 |  |  
                  | Environmental
 
                    
                      | Test Name | Test Values ∆R | Norms |  
                      | Temperature Cycling  | -40ºC + 70ºC, ≤ 2.5  mΩ | IEC 60 512 6-11dIEC 68-2-14-Na
 |  
                      | Temperature Cycling with Humidity | < 1 mΩ≤ 2.5 mΩ
 | ASTM 539-96IEC 68-2-3-Ca
 |  
                      | H2S - Industry Gas Testing | < 1 mΩ≤ 2.5 mΩ
 | ASTM 539-96IEC 68-2-42
 |  
                      | Salt Fog Exposure | < 1 mΩ≤ 2.5 mΩ
 | ASTM 539-96IEC 60-512-6-6
 IEC 68-2-11
 |  
                      | Chemical Resistance | < 1 mΩ≤ 2.5 mΩ
 | ASTM 539-96IEC 352-4-12
 |  Insertion Loss
 
 
                    
                        | Test Name | Test Values | 
                          DIN EN 50173 |  
                        | Frequency (MHz) | CAT 5  120Ω
                          dB |  
                        | 1 | ≤ 0.1 |  
                        | 4 | ≤ 0.1 |  
                        | 10 | ≤ 0.1 |  
                        | 16 | ≤ 0.2 |  
                        | 20 | ≤ 0.2 |  
                        | 31.25 | ≤ 0.2 |  
                        | 62.5 | ≤ 0.3 |  
                        | 100 | ≤ 0.4 |  Near-End Cross Talk
 
 
                      
                        | Test Name | Test Values | 
                            DIN EN 50173 |  
                        | Frequency (MHz) | CAT 5  120Ω
                          dB |  
                        | 1 | ≤ - 65 |  
                        | 4 | ≤ - 65 |  
                        | 10 | ≤ - 60 |  
                        | 16 | ≤ - 56 |  
                        | 20 | ≤ - 54 |  
                        | 31.25 | ≤ - 50 |  
                        | 62.5 | ≤ - 44 |  
                        | 100 | ≤ - 40 |  Return Loss
 
 
                      
                        | Test Name | Test Values | 
                            DIN EN 50173 |  
                        | Frequency (MHz) | CAT 5  120Ω
                          dB |  
                        | > 1.0 MHz | ≤ - 23 |  
                        | < 20 | ≤ - 23 |  
                        | ≥ 20 | ≤ - 14 |  
                        | ≤100 | ≤ - 14 |  |  |  